{"id":32837,"date":"2024-12-18T07:48:14","date_gmt":"2024-12-18T06:48:14","guid":{"rendered":"https:\/\/swiss-energypark.com\/?p=32837"},"modified":"2026-03-05T09:50:35","modified_gmt":"2026-03-05T08:50:35","slug":"pv-bench-solarmodule-auf-dem-mont-soleil-unter-die-lupe-genommen","status":"publish","type":"post","link":"https:\/\/swiss-energypark.com\/de\/pv-bench-solarmodule-auf-dem-mont-soleil-unter-die-lupe-genommen\/","title":{"rendered":"PV-Bench: Solarmodule auf dem Mont-Soleil unter die Lupe genommen"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1296px;margin-left: calc(-8% \/ 2 );margin-right: calc(-8% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.68%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.68%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:3.68%;--awb-spacing-left-medium:3.68%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-one\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h1 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><h1>PV-Bench: Solarmodule auf dem Mont-Soleil unter die Lupe genommen<\/h1><\/h1><\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"2560\" height=\"1440\" title=\"20230504_161648\" src=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-scaled.jpg\" alt class=\"img-responsive wp-image-32849\" srcset=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-200x113.jpg 200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-400x225.jpg 400w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-600x338.jpg 600w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-800x450.jpg 800w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-1200x675.jpg 1200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-scaled.jpg 2560w\" sizes=\"(max-width: 640px) 100vw, 1200px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-four\" style=\"--awb-margin-top:10px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h4 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><strong>Das Pilotprojekt \u201ePV-Bench 23-24\u201c auf dem Mont-Soleil zielt darauf ab, die Leistung verschiedener Photovoltaik (PV)-Module zu vergleichen. Nach mehr als einem Jahr Testphase zeigen die Ergebnisse deutliche Unterschiede, doch die Qualit\u00e4t des Schweizer Moduls sticht heraus. Um diese Genauigkeit zu erreichen, wurde ein Testprotokoll entworfen, eine Methode zur Datenfilterung erarbeitet und ein Messger\u00e4t speziell von der Berner Fachhochschule (BFH) entwickelt. <\/strong><\/h4><\/div><div class=\"fusion-text fusion-text-1\"><p>Seit \u00fcber drei\u00dfig Jahren produziert das Photovoltaikkraftwerk auf dem Mont-Soleil Strom. Urspr\u00fcnglich sollte es die Machbarkeit der Solartechnologie beweisen. Heute weist die 32 Jahre alte Anlage eine Leistungsverschlechterung von weniger als 8 % auf und liegt damit weit \u00fcber den damaligen Garantien. Ist diese Anlage heute noch relevant, da die meisten Photovoltaikmodule aus China kommen und die Technologie der 90er Jahre vom Markt verschwunden ist?<\/p>\n<p>Um diese Frage zu beantworten, haben die Gesellschaft Mont-Soleil, der Espace d\u00e9couverte \u00c9nergie und die Berner Fachhochschule (BFH) das Pilotprojekt \u201ePV Bench Mont-Soleil\u201c gestartet. Ziel des Projekts ist es, die Qualit\u00e4t von Solarmodulen in einem Umfeld zu bewerten, in dem die Kosten gesunken sind und die Frage nach ihrer Zuverl\u00e4ssigkeit und Nachhaltigkeit immer dr\u00e4ngender wird.<\/p>\n<p><strong>Sorgf\u00e4ltig ausgew\u00e4hlte Panelmodelle<\/strong><\/p>\n<p>Im Rahmen des Projekts sollten 6 markt\u00fcbliche PV-Modelle von 5 verschiedenen Herstellern getestet werden, die 3 konkurrierende Technologien abdecken:<\/p>\n<ul>\n<li>Jinko Solar, Tiger Neo, 430 W<\/li>\n<li>Meyer Burger, bifacial, 375 W<\/li>\n<li>Meyer Burger, weiss, 385 W<\/li>\n<li>Ja Solar, JAM60S20, 385 W<\/li>\n<li>3S, MegaSlate II, 195 W<\/li>\n<\/ul>\n<p>Die Auswahl umfasst Module aus China (Jinko Solar und Ja Solar), Deutschland (Meyer Burger) und der Schweiz (3S). Die Zellen verwenden die Technologien TOPCon (Jinko Solar), HJT (Meyer Burger) und PERC (Ja Solar und 3S).<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\"><p><strong>Ein hochpr\u00e4zises Testger\u00e4t<\/strong><\/p>\n<p>Um zuverl\u00e4ssige Ergebnisse zu gew\u00e4hrleisten, wurde eine Testtabelle konstruiert. Zus\u00e4tzlich zu den Messungen, die mit Pyranometern gesammelt wurden, um die von einem PV-Modul erzeugte Leistung mit der Einstrahlung zu vergleichen, wurde von den BFh-Studenten in Zusammenarbeit mit dem PV-Labor der BFh ein spezielles Ger\u00e4t entwickelt (siehe Foto 1). Dieses neue Ger\u00e4t mit dem Namen \u201eIV-Curve-Tracer IVCT\u201c funktioniert folgenderma\u00dfen: Jedes PV-Modul wird im Normalbetrieb an einen Mikro-Wechselrichter angeschlossen, wie bei einer Balkon-Solaranlage. Somit besteht PV-Bench also aus 30 Balkon-Solaranlagen, wodurch sichergestellt wird, dass sich die Module nicht gegenseitig beeinflussen. Jede Minute werden die Module vom Wechselrichter getrennt, damit der IVCT 100 Millisekunden lang die Leerlaufspannung, den Kurzschlussstrom und die Kennlinie der Module messen kann.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1296px;margin-left: calc(-8% \/ 2 );margin-right: calc(-8% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"1440\" height=\"2560\" title=\"20230504_150854\" src=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-scaled.jpg\" alt class=\"img-responsive wp-image-32846\" srcset=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-200x356.jpg 200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-400x711.jpg 400w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-600x1067.jpg 600w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-800x1422.jpg 800w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-1200x2133.jpg 1200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-scaled.jpg 1440w\" sizes=\"(max-width: 640px) 100vw, 600px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-3\"><p>Foto von \u201eIV-Curve Tracer IVCT\u201c &#8211; ein speziell f\u00fcr diese Forschung entwickeltes Messger\u00e4t<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"606\" height=\"456\" title=\"PVBencGraph\" src=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph.png\" alt class=\"img-responsive wp-image-32843\" srcset=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph-200x150.png 200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph-400x301.png 400w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph-600x451.png 600w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph.png 606w\" sizes=\"(max-width: 640px) 100vw, 600px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4\"><p>Beispiel einer Spannungs-Strom-Kurve, die mit dem Ger\u00e4t \u201eIV Curve Tracer IVCT\u201c gemessen wurde<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1296px;margin-left: calc(-8% \/ 2 );margin-right: calc(-8% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.68%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.68%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:3.68%;--awb-spacing-left-medium:3.68%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-5\"><p><strong>Reduzieren Sie die Datenmenge, ohne an Genauigkeit zu verlieren<\/strong><\/p>\n<p>Eine statistische Analyse erm\u00f6glichte es, die Anzahl der gemessenen Punkte zu reduzieren, ohne die Genauigkeit der Ergebnisse zu beeintr\u00e4chtigen. So wurde eine Dimensionsreduktion um den Faktor 100 vorgenommen, um \u201enur\u201c 100 Messpunkte pro Minute und PV-Modul zu verarbeiten.<\/p>\n<p>Diese 100 Punkte bilden eine Kurve, die Strom und Spannung in Beziehung zueinander setzt. Sie erm\u00f6glichen es, die Leistung eines Solarmoduls zu bewerten. Aus der Messkurve werden relevante Punkte wie die maximale Leistung, die das Modul erzeugen kann, der Kurzschlussstrom und die Leerlaufspannung extrahiert. Schlie\u00dflich wurde eine Degradationsfunktion verwendet, um die Verschlechterung der Modulleistung im Laufe der Zeit zu quantifizieren, indem verschiedene Variablen integriert wurden.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Langfristige Messungen unter realen Bedingungen<\/strong><\/p>\n<p>Eines der Ziele dieser Forschung ist es, genaue Langzeitmessungen unter realen Bedingungen zu verl\u00e4sslich zu machen. Diese Messungen sind unerl\u00e4sslich, um die Haltbarkeit und Effizienz von PV-Anlagen im Laufe der Zeit zu verstehen. Allerdings sind diese Messungen anf\u00e4llig f\u00fcr verschiedene Arten von Fehlern, die ihre Zuverl\u00e4ssigkeit beeintr\u00e4chtigen.<\/p>\n<p>Um dem entgegenzuwirken, wurde eine Methode zur Datenfilterung parametrisiert und angewendet. Sie erm\u00f6glicht :<\/p>\n<ul>\n<li>Ausrei\u00dfer und nicht repr\u00e4sentative Daten eliminieren<\/li>\n<li>Reduzieren Sie das Messrauschen, um stabilere Ergebnisse zu erzielen.<\/li>\n<li>Identifizierung und Ausschluss von Effekten, die nicht mit der tats\u00e4chlichen Degradation der Platten zusammenh\u00e4ngen, wie z. B. Daten, die bei sehr geringer Bestrahlung erhoben wurden<\/li>\n<\/ul>\n<p>Schlie\u00dflich lassen sich aus den gesammelten und gefilterten Daten zahlreiche wissenschaftliche Schlussfolgerungen \u00fcber PV-Module ziehen. So k\u00f6nnen die Leistung und der Wirkungsgrad sowie der interne Zustand der Module bewertet werden. Die Qualit\u00e4t und Genauigkeit der Daten erm\u00f6glicht es zum Beispiel, die Verschlechterung der L\u00f6tstellen der Verbindungsleisten zu messen, die die Solarzellen miteinander verbinden.<\/p>\n<p><strong>Ergebnisse und Schlussfolgerung<\/strong><\/p>\n<p>Obwohl nach einem Jahr Betrieb noch keine Schlussfolgerungen \u00fcber die Lebensdauer der Module gezogen werden k\u00f6nnen, wurden erste Erkenntnisse gewonnen, die mit den Ergebnissen anderer Forschungsprojekte \u00fcbereinstimmen:<\/p>\n<ul>\n<li>Der Trend zu \u201eimmer weniger Inhalt in der Verpackung\u201c zeigt sich auch in der Welt der PV-Module. Der Schweizer Hersteller 3S ist der einzige, der genau die versprochene Leistung erbringt, w\u00e4hrend die anderen Module eine Toleranzabweichung von 2-3 % aufweisen.<\/li>\n<li>Die bew\u00e4hrten PERC-Technologien von 3S und JA Solar zeigen die geringsten Leistungseinbu\u00dfen. TOPConet HJT hingegen zeigen nach einem Jahr einen gewissen Leistungsabfall.<\/li>\n<li>Das Glas-Glas-Modul liefert eine stabilere Leistung als das Glas-Folien-Modul. Dieses Ergebnis ist nicht unerwartet: Die Glasr\u00fcckseite bietet einen besseren Schutz als die herk\u00f6mmliche Folie.<\/li>\n<\/ul>\n<p>Schlie\u00dflich offenbart PV-Bench eine Herausforderung: Die meisten der getesteten Produkte sind bereits nicht mehr auf dem Markt erh\u00e4ltlich. Die Ergebnisse sind daher nicht besonders repr\u00e4sentativ f\u00fcr die Auswahl von Modulen in einem PV-Projekt. Sie erh\u00f6hen jedoch den Druck auf die Hersteller, qualitativ hochwertige Module zu produzieren. Und genau das ist eines der Hauptziele von PV-Bench: Produkte zu vergleichen, um die Qualit\u00e4t von PV-Anlagen zu verbessern.<\/p>\n<p>Weitere Informationen \u00fcber das Pilotprojekt PV Bench: www.pv-bench.ch<\/p>\n<\/div><div class=\"fusion-text fusion-text-6\"><p>Dr. Christof Bucher, Professor f\u00fcr photovoltaische Systeme &#8211; Berner Fachhochschule<\/p>\n<p>Laurent Raeber, Directeur Swiss Energypark et Soci\u00e9t\u00e9 Mont-Soleil<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":32849,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[134,19,61],"tags":[118,143,145],"class_list":["post-32837","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-feature-project-de","category-big-blog-de","category-projects","tag-exergue-2","tag-feature","tag-research"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/posts\/32837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/comments?post=32837"}],"version-history":[{"count":8,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/posts\/32837\/revisions"}],"predecessor-version":[{"id":33321,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/posts\/32837\/revisions\/33321"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/media\/32849"}],"wp:attachment":[{"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/media?parent=32837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/categories?post=32837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/swiss-energypark.com\/de\/wp-json\/wp\/v2\/tags?post=32837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}