{"id":32836,"date":"2024-12-18T16:09:10","date_gmt":"2024-12-18T15:09:10","guid":{"rendered":"https:\/\/swiss-energypark.com\/?p=32836"},"modified":"2026-03-05T01:24:57","modified_gmt":"2026-03-05T00:24:57","slug":"pv-bench","status":"publish","type":"post","link":"https:\/\/swiss-energypark.com\/fr\/pv-bench\/","title":{"rendered":"PV-Bench : des modules solaires pass\u00e9s au crible du Mont-Soleil"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1296px;margin-left: calc(-8% \/ 2 );margin-right: calc(-8% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.68%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.68%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:3.68%;--awb-spacing-left-medium:3.68%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-text fusion-title-size-one\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h1 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><h1>PV-Bench : des modules solaires pass\u00e9s au crible du Mont-Soleil<\/h1><\/h1><\/div><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\"><img decoding=\"async\" width=\"2560\" height=\"1440\" title=\"20230504_161648\" src=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-scaled.jpg\" alt class=\"img-responsive wp-image-32847\" srcset=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-200x113.jpg 200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-400x225.jpg 400w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-600x338.jpg 600w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-800x450.jpg 800w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-1200x675.jpg 1200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_161648-scaled.jpg 2560w\" sizes=\"(max-width: 640px) 100vw, 1200px\" \/><\/span><\/div><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-text fusion-title-size-four\" style=\"--awb-margin-top:10px;--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h4 class=\"fusion-title-heading title-heading-left\" style=\"margin:0;\"><strong>Le projet pilote \u00ab PV-Bench 23-24\u00bb sur le Mont-Soleil vise \u00e0 comparer les performances de diff\u00e9rents modules photovolta\u00efques (PV). Apr\u00e8s plus d\u2019un an de tests, les r\u00e9sultats montrent des diff\u00e9rences significatives, mais la qualit\u00e9 du module suisse se d\u00e9marque. Pour atteindre cette pr\u00e9cision, un protocole de test a \u00e9t\u00e9 con\u00e7u, une m\u00e9thodologie de filtrage des donn\u00e9es \u00e9labor\u00e9e et un appareil de mesure sp\u00e9cialement d\u00e9velopp\u00e9 par la Haute \u00c9cole Sp\u00e9cialis\u00e9e Bernoise (BFH).<\/strong><\/h4><\/div><div class=\"fusion-text fusion-text-1\"><p>Depuis plus de trente ans, la centrale photovolta\u00efque de Mont-Soleil produit de l\u2019\u00e9lectricit\u00e9. Initialement, son objectif \u00e9tait de prouver la faisabilit\u00e9 de la technologie solaire. Aujourd\u2019hui, cette installation vieille de 32 ans affiche une d\u00e9gradation des performances inf\u00e9rieure \u00e0 8 %, soit bien au-del\u00e0 des garanties de l\u2019\u00e9poque. Cette installation est-elle encore pertinente aujourd\u2019hui alors que la majorit\u00e9 des modules photovolta\u00efques viennent de Chine et que la technologie des ann\u00e9es 90 a disparu du march\u00e9 ?<\/p>\n<p>Pour r\u00e9pondre \u00e0 cette question, la Soci\u00e9t\u00e9 Mont-Soleil, l\u2019Espace d\u00e9couverte \u00c9nergie et la Haute \u00c9cole Sp\u00e9cialis\u00e9e Bernoise (BFH) ont lanc\u00e9 le projet pilote \u00ab PV Bench Mont-Soleil \u00bb. Ce projet vise \u00e0 \u00e9valuer la qualit\u00e9 des modules solaires dans un contexte o\u00f9 leur co\u00fbt a chut\u00e9 et o\u00f9 la question de leur fiabilit\u00e9 et de leur durabilit\u00e9 se pose avec plus d\u2019insistance.<\/p>\n<p><strong>Des mod\u00e8les de panneaux soigneusement s\u00e9lectionn\u00e9s<\/strong><\/p>\n<p>Le projet s\u2019est propos\u00e9 de tester 6 mod\u00e8les de panneaux PV du march\u00e9, produits par 5 fournisseurs diff\u00e9rents et couvrant 3 technologie concurrentes\u00a0:<\/p>\n<ul>\n<li>Jinko Solar, Tiger Neo, 430 W<\/li>\n<li>Meyer Burger, bifacial, 375 W<\/li>\n<li>Meyer Burger, blanc, 385 W<\/li>\n<li>Ja Solar, JAM60S20, 385 W<\/li>\n<li>3S, MegaSlate II, 195 W<\/li>\n<\/ul>\n<p>La s\u00e9lection inclut des modules chinois (Jinko Solar et Ja Solar), allemands (Meyer Burger) et suisse (3S). Les cellules utilisent les technologies TOPCon (Jinko Solar), HJT (Meyer Burger) et PERC (Ja Solar et 3S).<\/p>\n<\/div><div class=\"fusion-text fusion-text-2\"><p><strong>Un dispositif de test de haute pr\u00e9cision<\/strong><\/p>\n<p>Pour garantir des r\u00e9sultats fiables, une table de test a \u00e9t\u00e9 construite. En plus des mesures r\u00e9colt\u00e9es par des pyranom\u00e8tres qui permettent de comparer la puissance produite par un panneau PV avec l\u2019irradiation, un appareil sp\u00e9cifique a \u00e9t\u00e9 d\u00e9velopp\u00e9 par les \u00e9tudiants de la BFh en collaboration avec le laboratoire PV de la BFh (voir Photo 1). Ce nouvel appareil appel\u00e9 \u00ab IV-Curve-Tracer IVCT \u00bb fonctionne de la mani\u00e8re suivante : chaque module PV est connect\u00e9 \u00e0 un micro-onduleur en fonctionnement normal, comme dans une installation solaire de balcon. Ainsi, PV-Bench se compose donc de 30 installations solaires de balcon, garantissant que les modules ne s\u2019influencent pas mutuellement. Chaque minute, les modules sont d\u00e9connect\u00e9s de l\u2019onduleur pour permettre \u00e0 l\u2019IVCT de mesurer pendant 100 millisecondes la tension en circuit ouvert, le courant de court-circuit et la courbe caract\u00e9ristique des modules.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1296px;margin-left: calc(-8% \/ 2 );margin-right: calc(-8% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-2 hover-type-none\"><img decoding=\"async\" width=\"1440\" height=\"2560\" title=\"20230504_150854\" src=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-scaled.jpg\" alt class=\"img-responsive wp-image-32844\" srcset=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-200x356.jpg 200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-400x711.jpg 400w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-600x1067.jpg 600w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-800x1422.jpg 800w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-1200x2133.jpg 1200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/20230504_150854-scaled.jpg 1440w\" sizes=\"(max-width: 640px) 100vw, 600px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-3\"><p>Photo de \u00ab\u00a0IV-Curve Tracer IVCT\u00a0\u00bb \u2013 appareil de mesure d\u00e9velopp\u00e9 sp\u00e9cifiquement pour cette recherche<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-image-element \" style=\"--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-3 hover-type-none\"><img decoding=\"async\" width=\"606\" height=\"456\" title=\"PVBencGraph\" src=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph.png\" alt class=\"img-responsive wp-image-32841\" srcset=\"https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph-200x150.png 200w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph-400x301.png 400w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph-600x451.png 600w, https:\/\/swiss-energypark.com\/wp-content\/uploads\/2024\/12\/PVBencGraph.png 606w\" sizes=\"(max-width: 640px) 100vw, 600px\" \/><\/span><\/div><div class=\"fusion-text fusion-text-4\"><p>Exemple de courbe tension-courant mesur\u00e9e par l\u2019appareil \u00ab\u00a0IV Curve Tracer IVCT\u00a0\u00bb<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1296px;margin-left: calc(-8% \/ 2 );margin-right: calc(-8% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:3.68%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:3.68%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:3.68%;--awb-spacing-left-medium:3.68%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-5\"><p><strong>R\u00e9duire la quantit\u00e9 de donn\u00e9es, sans perdre en pr\u00e9cision<\/strong><\/p>\n<p>Une analyse statistique a permis de r\u00e9duire la quantit\u00e9 de points mesur\u00e9s sans alt\u00e9rer la pr\u00e9cision des r\u00e9sultats. Ainsi une r\u00e9duction de dimensionalit\u00e9 d\u2019un facteur 100 a \u00e9t\u00e9 appliqu\u00e9e afin de ne traiter \u00ab\u00a0que\u00a0\u00bb 100 points de mesure par minutes et par panneau photovolta\u00efque.<\/p>\n<p>Ces 100 points forment une courbe qui met en relation le courant et la tension. Ils permettent d\u2019\u00e9valuer les performance d\u2019un module solaire. De la courbe de mesure sont extrait des points pertinents comme la puissance maximale que le module peut produire, le courant de court-circuit et la tension de circuit ouvert. Finalement une fonction de d\u00e9gradation a \u00e9t\u00e9 utilis\u00e9e afin de quantifier la d\u00e9t\u00e9rioration des performances du module au cours du temps en int\u00e9grant diff\u00e9rentes variables.<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<p><strong>Mesures \u00e0 long terme en conditions r\u00e9elles<\/strong><\/p>\n<p>Un des objectifs de cette recherche est de fiabiliser des mesures pr\u00e9cises \u00e0 long terme en conditions r\u00e9elles. En effet, ces derni\u00e8res sont essentielles pour comprendre la durabilit\u00e9 et l\u2019efficacit\u00e9 des installations PV au fil du temps. Cependant, ces mesures sont sujettes \u00e0 diverse types d\u2019erreur qui r\u00e9duisent leur fiabilit\u00e9.<\/p>\n<p>Pour pallier cela, une m\u00e9thode de filtration des donn\u00e9es a \u00e9t\u00e9 param\u00e9tr\u00e9e et appliqu\u00e9e. Elle permet de\u00a0:<\/p>\n<ul>\n<li>\u00c9liminer les valeurs aberrantes et les donn\u00e9es non repr\u00e9sentatives<\/li>\n<li>R\u00e9duire le bruit de mesure pour obtenir des r\u00e9sultats plus stables<\/li>\n<li>Identifier et exclure les effets non li\u00e9s \u00e0 la d\u00e9gradation r\u00e9elle des panneaux telles que \u2013 par exemple &#8211; les donn\u00e9es recueillies lors d\u2019une irradiation tr\u00e8s faible<\/li>\n<\/ul>\n<p>Finalement, les donn\u00e9es r\u00e9colt\u00e9es et filtr\u00e9es permettent de tirer de nombreuses conclusions scientifiques sur les modules PV. On peut ainsi \u00e9valuer la performance et le rendement ainsi que l\u2019\u00e9tat interne des modules. La qualit\u00e9 et la pr\u00e9cision des donn\u00e9es permettent \u2013 par exemple &#8211; de mesurer la d\u00e9gradation des soudures des barrettes de connexion qui lient les cellules solaires.<\/p>\n<p><strong>R\u00e9sultats et conclusion<\/strong><\/p>\n<p>Apr\u00e8s une ann\u00e9e de fonctionnement, bien que des conclusions sur la dur\u00e9e de vie des modules ne puissent encore \u00eatre tir\u00e9es, des premiers enseignements ont \u00e9t\u00e9 obtenus, en accord avec les r\u00e9sultats d\u2019autres projets de recherche :<\/p>\n<ul>\n<li>La tendance \u00e0 \u00ab toujours moins de contenu dans l\u2019emballage \u00bb se manifeste aussi dans l\u2019univers des modules PV. Le fabricant suisse 3S est le seul \u00e0 fournir exactement la performance promise, tandis que les autres modules pr\u00e9sentent une diff\u00e9rence de 2-3 % dans les tol\u00e9rances.<\/li>\n<li>Les technologies \u00e9prouv\u00e9es PERC de 3S et JA Solar montrent le moins de pertes de performance. En revanche, TOPCon et HJT affichent une certaine baisse de performance apr\u00e8s un an.<\/li>\n<li>Le module en verre-verre fournit des performances plus stables que le module en verre-film. Ce r\u00e9sultat n\u2019est pas inattendu : la face arri\u00e8re en verre offre une meilleure protection que le film traditionnel.<\/li>\n<\/ul>\n<p>Enfin, PV-Bench r\u00e9v\u00e8le un d\u00e9fi : la plupart des produits test\u00e9s ne sont d\u00e9j\u00e0 plus disponibles sur le march\u00e9. Les r\u00e9sultats ne sont donc pas particuli\u00e8rement repr\u00e9sentatifs pour le choix de modules dans un projet PV. Toutefois, ils augmentent la pression sur les fabricants pour qu\u2019ils produisent des modules de qualit\u00e9. Et c\u2019est pr\u00e9cis\u00e9ment l\u2019un des principaux objectifs de PV-Bench : comparer les produits pour am\u00e9liorer la qualit\u00e9 des installations PV.<\/p>\n<p>Pour en savoir plus au sujet du projet pilote PV Bench\u00a0: www.pv-bench.ch<\/p>\n<\/div><div class=\"fusion-text fusion-text-6\"><p>Dr. Christof Bucher, Professeur des syst\u00e8mes photovoltaiques \u2013 Berner Fachhoch Schule<\/p>\n<p>Laurent Raeber, Directeur Swiss Energypark et Soci\u00e9t\u00e9 Mont-Soleil<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_2 1_2 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:50%;--awb-margin-top-large:0px;--awb-spacing-right-large:7.36%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:7.36%;--awb-width-medium:50%;--awb-order-medium:0;--awb-spacing-right-medium:7.36%;--awb-spacing-left-medium:7.36%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:3.68%;--awb-spacing-left-small:3.68%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><\/div><\/div><\/div><\/div><\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":5,"featured_media":32847,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[101,43,63],"tags":[117,142,141],"class_list":["post-32836","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-feature-project-fr","category-big-blog-fr","category-projects-fr","tag-exergue","tag-feature","tag-research"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/posts\/32836","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/comments?post=32836"}],"version-history":[{"count":2,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/posts\/32836\/revisions"}],"predecessor-version":[{"id":32851,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/posts\/32836\/revisions\/32851"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/media\/32847"}],"wp:attachment":[{"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/media?parent=32836"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/categories?post=32836"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/swiss-energypark.com\/fr\/wp-json\/wp\/v2\/tags?post=32836"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}